6 - 6
–
+
ELEC
ELECTRIC STARTING SYSTEM
STARTING CIRCUIT CUT-OFF SYSTEM
OPERATION
If the main switch is set to “ON”, the starter
motor can only operate if at least one of the
following conditions is met:
●
The transmission is in neutral (the neutral
switch is closed).
●
The clutch lever is pulled to the handlebar
(the clutch switch is closed).
The starting circuit cut-off relay prevents the
starter motor from operating when neither of
these conditions has been met. In this
instance, the starting circuit cut-off relay is
open so current cannot reach the starter
motor. When at least one of the above condi-
tions has been met the starting circuit cut-off
relay is closed and the engine can be started
by pressing the start switch.
WHEN THE TRANSMISSION IS
IN NEUTRAL
WHEN THE CLUTCH LEVER IS
PULLED TO THE HANDLEBAR
1
Battery
2
Main fuse
3
Main switch
4
Start switch
5
Starting circuit cut-off relay
6
Neutral switch
7
Clutch switch
8
Starter relay
9
Starter motor
1
2
M
3
8
5
4
6
9
7
ELECTRIC STARTING SYSTEM
Содержание TT-R125E(R)
Страница 22: ...INDEX GENERAL INFORMATION SPECIFICATIONS REGULAR INSPECTION AND ADJUSTMENTS ENGINE CHASSIS ELECTRICAL...
Страница 47: ...GEN INFO MEMO...
Страница 147: ...SPEC MEMO...
Страница 169: ...INSP ADJ MEMO...
Страница 236: ...3 37 INSP ADJ Charging method using a variable voltage charger BATTERY INSPECTION AND CHARGING...
Страница 237: ...3 38 INSP ADJ Charging method using a constant voltage charger BATTERY INSPECTION AND CHARGING...
Страница 290: ...4 23 ENG CAMSHAFT AND ROCKER ARMS 5 Install Camshaft bearing holder 1 Bolt 2 T R 10 Nm 1 0 m kg 7 2 ft lb LT...
Страница 541: ...ELEC MEMO...
Страница 553: ...ELEC MEMO...
Страница 573: ...ELEC MEMO...
Страница 576: ......
Страница 577: ......
Страница 578: ...PRINTED IN JAPAN 2002 11 0 7 1 CR E F G PRINTED ON RECYCLED PAPER YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN...