For Service Technician Use Only
DIAGNOSTICS AND TROUBLESHOOTING (Cont.)
Whirlpool
®
and KitchenAid
®
Filtration and Maytag
®
24" Microfiltration Dishwashers
n
2-11
Troubleshooting Guide (Continued)
CUSTOMER DESCRIPTION
POTENTIAL CAUSES
CHECK
RELATED
ERROR
CODES
Won't start and Start/Resume
LED flashes 3 times when
Start/Resume key is pressed
Control looking for door to open
between cycles:
˗ Customer has not opened door since
last cycle
˗ Door switch contacts stuck closed
Refer to “
” table.
F5E2
Won't accept key presses and
Control Lock LED on
Control lockout feature accidentally
enabled by customer.
Instruct customer. Refer to
. Press and hold Control Lock key
for 5 seconds to disable lockout feature.
One or more keys won't
respond or unusual key/LED/
display behavior
Stuck key or short circuits in keypad or
in user interface's input lines that read
the keys.
Refer to “
” table.
F2E1
Capacitive touch keypad adhesive
coming loose from console.
1. Unplug dishwasher or disconnect
power.
2. Inspect keypad board for separation
from console. Replace keypad/console
if separation is seen.
Loose connections between keypad and
control and/or bent connector pins.
1. Unplug dishwasher or disconnect
power.
2. Inspect connections in user interface
circuits. Reconnect loose connections.
Replace parts if pins are damaged or
contaminated.
F6E1
Excessive condensation on user interface
parts due to vent and/or fan problem.
Check fault code history for vent and/or
fan faults. Refer to “
table. Verify that vent closes and fan turns
on. Refer to "Leaks or drips on cabinet or
floor."
F10E2 (FAE2)
F10E3 (FAE3)
User interface failure.
1. Unplug dishwasher or disconnect
power.
2. Replace user interface.
Dishwasher beeps constantly
User opened door during cycle and
closed door without pressing
Start/Resume key to resume cycle.
Instruct customer. Control is designed to
beep if dishwasher is in "cycle interrupt"
mode with door latched. Control will stop
beeping when door is open and/or when
Start/Resume key is pressed to resume
cycle.
Normal beeper operation is excessive to
customer.
Instruct customer how to turn beeper off
and on. Refer to
.
Control is programmed to stop cycle and
alert customer when certain fault codes
have been detected.
Press Cancel key once to silence alarm
during fault mode. Read error code from
the dishwasher and refer to “
” table. Use service diagnostics
mode to get fault history from appliance.
F1E1
F7E1
F7E2
F8E1
F8E4
F8E5
F9E1
F10E5 (FAE5)
LEDs or displays run for a
short time without loads
running or wash motor runs
without attempt to fill or fan
is the only load that runs
Unit is in sales demo mode
Check operation of Cancel key. If pressing
cancel multiple times does not activate
Cancel/Drain sequence, unit is likely in
sales demo mode. To clear demo mode,
cycle power for at least 1 minute or run
service diagnostics cycle.
Open fuse on control removed power
from loads
Содержание M-17