For Service Technician Use Only
COMPONENT TESTING(Cont.)
Whirlpool
®
and KitchenAid
®
Filtration and Maytag
®
24" Microfiltration Dishwashers
n
3-3
Wiring Diagram
IMPORTANT:
Electrostatic discharge may cause damage to machine control electronics.
Check for proper voltage by completing the following steps:
1.
Unplug (product) or disconnect power.
2.
Connect voltage measurement equipment to proper connectors.
3.
Plug in (product) or reconnect power and confirm voltage reading.
4.
Unplug (product) or disconnect power.
Maytag® DW03G-P3 SS Rotating Inlet Filter
12 V
Drive
12 V
Drive
12 V
Drive
12 V
Drive
HTR-L
RELAY
HTR-N
RELAY
PILOT
RELAY
WH
wire
N
L1
HEATER
H.L.STAT
BU/WH
wire
BU/RD
wire
BK wire
Fuse
(On some Models)
P5
BR
M
DRAIN
MOTOR
120 V / 60 Hz
45 W, 0.65 A
27.4 - 32.2
Ω
120 V / 60 Hz
120 V / 60 Hz / 5 W
1200 - 1600
Ω
120 V / 60 Hz / 3 W
1100 - 1400
Ω
FILL VALVE
M
DIVERTER
SPRAY ARM MOTOR
(ON SOME MODELS)
120 V / 60 Hz / 6 W
1890 - 2310
Ω
EACH COIL
M
VENT
120 V / 60 Hz / 6 W
600 - 1800
Ω
DOOR SW
12 V
NORMALLY
OPEN
DISPENSER
120 V / 60 Hz
310 - 380
Ω
0.35 A
42 W
A-SYNCH
WASH
MOTOR
PUMP
120 V / 60 Hz
800 W WET / 500 W DRY
10 - 40
Ω
10 A 120 VAC
OPEN (C) - 90+/-3
CLOSE (C) - 70 +/-4
LT BU
P6 BU
P8 PK
P12 VT
P14 BR
Analog
Input
Door Open
Detection
MOTOR
RELAY
OR
OR
SMD
FUSE
FUSE
4
3
2
1
ELECTRONIC CONTROL
RELAY RETURN LINE THAT GOES THRU DOOR SWITCH
RELAY RETURN LINE THAT BYPASSES DOOR SWITCH
Triac Load Current Sensing
POWER
SUPPLY
VEE
VDD
REF
5 V
12 V
L
N
1
2
3
4
1
3
4
6
1
3
4
6
1
2
3
6
7
8
9
10 11
5
4
1
2
3
5
4
1
P9
RD
2
3
5
INPUT
NTC
INPUT
INPUT
INPUT
INPUT
OPT
SIG
TURB
DRIVE
PWM
6
7
4
1
P11 OR
2
3
5
6
7
4
1
GY
P1B
5 V
12 V
WIN
DATA
REF
P1A
WIN
DATA
(4p R2.5 header)
REF
2
3
4
1
WH
2
3
4
1
P10
O.W.I.
(NTC & Turbidity Sensor)
DIVERTER
SENSOR
12 V
SWITCHED
12 V
NORMALLY
CLOSED
(ON SOME MODELS)
12 V
SWITCHED
FLOW
METER
LEAKAGE
(FLOAT)
SWITCH
WiFi module
YL
2
3
5
6
4
N
L1
FAN MOTOR
(ON SOME MODELS)
12 V, 1 W
145 - 185 k
Ω
12 V
(ON SOME MODELS)
RINSE AID EMPTY &
MIDDLE SPRAY ARM
SENSOR
(ON SOME MODELS)
M
NTC
NON-SOIL SENSING
MODELS
Lower Spray Arm
Sensor
( On Some Models)
LIGHT IN
THE
TUB
12 V
PWM
OR
1
12 V 5 V Data GND
Front Status Display
(On Some Models)
External HMI
5 V
Data
GND
2
3
1 2
3
4
1
2
3
4
1
2
3
4
5
Reserved
GND
WIN data
5 V
12 V
P3
SERVICE
TOOL
12 V
BEEPER
PROGRAMS
OPTION A
OPTION B
(DELAY)
( 2 4 8 )
START
Resume
CANCEL
Drain
ALARMS
(Status)
INTEGRATED USER INTERFACE
MAX POSSIBLE POPULATION
5 KEYS, 14 LED's
1
2
3
4
P4
5 V
12 V
(On Some
Models)
ACU DIAGNOSTIC LED
(SEE TABLE BELOW)
(SEE NTC TABLE BELOW)
Содержание M-17
Страница 4: ...iv n Whirlpool and KitchenAid Filtration and Maytag 24 Microfiltration Dishwashers Notes ...
Страница 20: ...GENERAL INFORMATION 1 16 n Whirlpool and KitchenAid Filtration and Maytag 24 Microfiltration Dishwashers Notes ...
Страница 88: ...Whirlpool and KitchenAid Filtration and Maytag 24 Microfiltration Dishwashers W11447459 ...