For Service Technician Use Only
DIAGNOSTICS AND TROUBLESHOOTING (Cont.)
2-10
n
Whirlpool
®
and KitchenAid
®
Filtration and Maytag
®
24" Microfiltration Dishwashers
Troubleshooting Guide
NOTES:
n
For resistance checks, refer to the “Component Testing” in Section 3.
n
For checking operation with diagnostics, refer to “
Service Diagnostics Cycle Timing
” section.
CUSTOMER DESCRIPTION
POTENTIAL CAUSES
CHECK
RELATED
ERROR
CODES
CLEAN LED Flashes
Control Programmed with Self
Diagnostics.
Read error code from the dishwasher and
refer to “
” table. Run
service diagnostics test cycle to read full
history of error codes.
F1E1
F7E1
F7E2
F8E1
F8E4
F8E5
F9E1
F10E5 (FAE5)
Won't run or power up
("Dead" keypad/console)
n
No operation
n
No keypad response
n
No LEDs or display
No power to unit or bad connection.
Check fuses, circuit breakers, and junction
box connections.
Loose connections in dishwasher power
up circuit or between keypad(s) and
control.
1. Unplug dishwasher or disconnect
power.
2. Check continuity power connections
keypad(s) and control.
User interface on this model is not
compatible with control which has been
exchanged with a control from another
model.
Unplug dishwasher or disconnect power.
Verify correct control is installed for this
model. Control is specific to each user
interface and model type. Call techline
to verify part numbers if necessary. If
incorrect control, replace.
Control detected door switch problem.
Refer to “
” table.
F5E1
User interface or control failure.
1. Unplug dishwasher or disconnect
power.
2. Replace user interface/console and/or
control.
Won't run and Start/Resume
LED is blinking slowly
By design, if door is opened for more
than 5 seconds or power is interrupted
during a cycle, the user must press Start/
Resume to resume operation.
Instruct customer. Refer to
.
Start/Resume key not responding
See "One or more keys won't respond."
Control detected door switch problem.
Refer to “
” table.
F5E1
DANGER
Electrical Shock Hazard
Only authorized technicians should perform
diagnostic voltage measurements.
After performing voltage measurements,
disconnect power before servicing.
Failure to follow these instructions can result in