Vision MaxPro
186
© 2006 Vision Engraving Systems
Soak and clean the inside of the reservoir with a Clorox type solution if needed to remove
scale buildup. Rinse the reservoir with clean water, return the level indicator to a vertical
position and refill. Replace cover and ensure that the pump electrical cable and the water
feeding hose are positioned in the cut out provided in the cover.
Cleaning the vice rail and lead screw
Make sure that the vise locking screws are loose and press the “Shift” key.
Hold down the left arrow key to open the vise wide enough to expose as much of the vise
lead screw as possible. Inspect the vise lead screw for any debris build up and clean using
a paint brush and alcohol if needed. Apply a light layer silicon lubricant on the lead screw.
Partially close the vise by holding down the “right” arrow key to access the ends of the lead
screw and repeat the procedure.
Содержание MaxPro
Страница 5: ...Chapter I ...
Страница 11: ...Chapter II ...
Страница 23: ...Configuration 19 2006 Vision Engraving Systems 3 Click on the IP Address tab ...
Страница 60: ......
Страница 61: ...Chapter III ...
Страница 100: ...Vision MaxPro 96 2006 Vision Engraving Systems Mounting the item to be engraved ...
Страница 114: ...Vision MaxPro 110 2006 Vision Engraving Systems Select Finish The Plate Size screen will appear ...
Страница 137: ...Operations 133 2006 Vision Engraving Systems If No is clicked the program returns to the Flat plate dimension screen ...
Страница 179: ...Operations 175 2006 Vision Engraving Systems The Plot screen below will appear ...
Страница 182: ......
Страница 183: ...Chapter IV ...
Страница 191: ...Chapter V ...
Страница 202: ...Vision MaxPro 198 2006 Vision Engraving Systems W Windows 2000 15 Windows 98 18 Windows XP 12 ...
Страница 203: ......