4 Parameters
VFD700 AC Drive Getting Started Guide 59
4.3 Menu P00
In P00 parameter group, each P00.XX parameter is related with the parameter from other
menus. If the P00.XX parameter is changed, the related parameter will be changed too, and
vice versa. The parameters in the brackets are the related parameter codes.
Parameter ID
Parameter Name
Range
【
Default
】
Change Mode
P00.01 (P05.02)
Keypad cycle display mode
0
~
2
【
1
】
Run&Stop
0: Fixed mode
Keypad cycle display order: in standby or running state, the order of keypad cycle display will
not be changed.
P05.01
P05.13
P05.12
P05.14
P01.14
>>
>>
>>
>>
>>
ESC
ESC
ESC
ESC
1: Auto switch mode in running state
Keypad cycle display order: the order is shown in the figure below when the drive is standby;
when the drive is running, it will automatically switch to the cycle order of fixedmode.
P01.14
P05.13
P05.12
P05.14
P05.01
>>
>>
>>
>>
>>
ESC
ESC
ESC
ESC
2: Reserved
Parameter ID
Parameter Name
Range
【
Default
】
Change Mode
P00.02 (P05.03)
Parameter display
0
~
2
【
1
】
Stop Only
0: Only parameters in menu P00
1: All parameters
2: Only parameters which have different value with the defaults