P04.40
PLC step11
running time
0.0
~
6553.5
0.1
0.0
Run&Stop
01B7H
P04.41
PLC step11
Accel./
Decel. Rate
selector
0: Accel./Decel. rate 1
1: Accel./Decel. rate 2
2: Accel./Decel. rate 3
3: Accel./Decel. rate 4
1
0
Run&Stop
01B8H
P04.42
PLC step12
running time
0.0
~
6553.5
0.1
0.0
Run&Stop
01B9H
P04.43
PLC step12
Accel./
Decel. rate
selector
0: Accel./Decel. rate 1
1: Accel./Decel. rate 2
2: Accel./Decel. rate 3
3: Accel./Decel. rate 4
1
0
Run&Stop
01BAH
P04.44
PLC step13
running time
0.0
~
6553.5
0.1
0.0
Run&Stop
01BBH
P04.45
PLC step13
Accel./
Decel. rate
selector
0: Accel./Decel. rate 1
1: Accel./Decel. rate 2
2: Accel./Decel. rate 3
3: Accel./Decel. rate 4
1
0
Run&Stop
01BCH
P04.46
PLC step14
running time
0.0
~
6553.5
0.1
0.0
Run&Stop
01BDH
P04.47
PLC step14
Accel./
Decel. rate
selector
0: Accel./Decel. rate 1
1: Accel./Decel. rate 2
2: Accel./Decel. rate 3
3: Accel./Decel. rate 4
1
0
Run&Stop
01BEH
P04.48
PLC step15
running time
0.0
~
6553.5
0.1
0.0
Run&Stop
01BFH
P04.49
PLC step15
Accel./
Decel. rate
selector
0: Accel./Decel. rate 1
1: Accel./Decel. rate 2
2: Accel./Decel. rate 3
3: Accel./Decel. rate 4
1
0
Run&Stop
01C0H