![Veikong VFD700 Series Скачать руководство пользователя страница 139](http://html1.mh-extra.com/html/veikong/vfd700-series/vfd700-series_operation-manual_3864500139.webp)
Appendix
132VFD700 AC Drive Getting Started Guide
Menu P14: Textile function
ID
Function
Range
Step
Default
Change
Mode
Modbus
Register
Address
P14.01
Textile function
enable
0: Off
1: On
1
0
Stop Only
0578H
P14.02
Centre of textile
frequency
0.00Hz
~
Max.
frequency
0.01Hz
0.00Hz
Run&Stop
0579H
P14.03
Preset textile
frequency
0.00Hz
~
Max.
frequency
0.01Hz
0.00Hz
Run&Stop
057AH
P14.04
Run time of Preset
textile frequency
0.0s
~
3600.0s
0.1s
0.0s
Run&Stop
057BH
P14.05 Textile frequency
0.0%
~
50.0%
(map to P14.02)
0.1%
0.0%
Run&Stop
057CH
P14.06 Jump frequency
0.0%
~
50.0%
(map to P14.05)
0.1%
0.0%
Run&Stop
057DH
P14.07 Textile period
0.1 s
~
1000.0s
0.1s
10.0s
Run&Stop
057EH
P14.08 Triangle rise time
0.0%
~
100.0%
(map to P14.07)
0.1%
50.0%
Run&Stop
057FH
P14.09 Pause textile
0: Off
1: On
1
0
Run&Stop
0580H
P14.10
Reference of
length
0
~
P14.20
1
1000
Run&Stop
0581H
P14.11 Actual length
0
~
30000
1
Actual
Actual
0582H
P14.12
Pulse number per
unit length
0.1
~
P14.21
0.1
100.0
Run&Stop
0583H
P14.13
Actual length
meets the
reference
0: P14.11
<
P14.10
1: P14.11
≥
P14.10
1
Actual
Actual
0584H
P14.14
Reference of
number counting
1
~
P14.22
1
1000
Run&Stop
0585H
P14.15 Set number
1
~
P14.14
1
1000
Run&Stop
0586H