![Veikong VFD700 Series Скачать руководство пользователя страница 125](http://html1.mh-extra.com/html/veikong/vfd700-series/vfd700-series_operation-manual_3864500125.webp)
Appendix
118VFD700 AC Drive Getting Started Guide
Menu P09: Digital input and output
ID
Function
Range
Step
Default
Change
Mode
Modbus
Register
Address
P09.01
Digit input
function
level
control
0: P09.02 to P09.08 are
base application (0
~
19)
1: P09.02
~
P09.08 are
advanced application
(P00.00
~
P18.08)
1
0
Run&Stop
0384H
P09.02
DI1
function
0: Preset select bit 0
1: Preset select bit 1
2: Run
3: Run forward (FWD)
4: Run reverse (REV)
5: 3-wire enable
6: FWD/REV
7: Jog forward
8: UP
9: DOWN
10: Enable
11: Reset
12: Control channel is
switched to terminal
13: Reset length counting
14: Reset number
counting
15: External trip
16
:
Preset select bit2
17
:
Preset select bit3
18
:
PLC reset indicator
19: No function
99*: Advanced function
1
DI1: 3
Stop Only
0385H
P09.03
DI2
function
DI2: 4
0386H
P09.04
DI3
function
DI3: 7
0387H
P09.05
DI4
function
DI4: 0
0388H
P09.06
DI5
function
DI5: 1
0389H
P09.07
DI6
function
DI6: 10
038AH
P09.08
DI7
function
DI7: 11
038BH