Appendix
VFD700 AC Drive Getting Started Guide
121
ID
Function
Range
Step
Default
Change
Mode
Modbus
Register
Address
P09.29
Digital
output
function
level
control
0: P09.30
~
P09.31 is base
application (0
~
8)
1: P09.30
~
P09.31 is
advanced application
(P00.00
~
P18.08)
1
0
Run&Stop
03A0H
P09.30
DO1
function
0: PLC is running recycle
1: Drive is active
2: Drive is alarming
3: 100% current
4: Drive healthy
5: Length counting arrival
6: Running at zero speed
7: Brake logic is on
8: No function
99*: Advanced function
1
DO1: 6
Run&Stop
03A1H
P09.31
DO2
function
DO2: 2
03A2H
P09.32
DO1
inverter
0: Off
1: On
1
0
Run&Stop
03A3H
P09.33
DO2
inverter
0: Off
1: On
1
0
Run&Stop
03A4H
P09.34
DO2
maximum
frequency
of output
pulse
0.1kHz
~
50.0kHz
0.1
kHz
10.0kHz
Run&Stop
03A5H
P09.35
DO2 output
mode
selection
0: Digital signal output
1: Pulse output
2: PWM output
1
0
Run&Stop
03A6H
P09.36 Reserved
−
−
−
−
−
P09.37 Reserved
−
−
−
−
−