![Veikong VFD700 Series Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/veikong/vfd700-series/vfd700-series_operation-manual_3864500151.webp)
Appendix
144VFD700 AC Drive Getting Started Guide
Menu P18: Brake logic control
ID
Function
Range
Step
Default
Change
Mode
Modbus
Register
Address
P18.01
Brake controller
enable
0:
Off
1:
On
1
0
StopOnly
0708H
P18.02
Brake release current
threshold
0%
~
200%
1%
50%
Run&Stop
0709H
P18.03
Brake apply current
threshold
0%
~
200%
1%
10%
Run&Stop
070AH
P18.04
Brake release
frequency threshold
0.00Hz
~
20.00Hz
0.01Hz
1.00Hz
Run&Stop
070BH
P18.05
Brake apply
frequency threshold
0.00Hz
~
20.00Hz
0.01Hz
2.00Hz
Run&Stop
070CH
P18.06
Pre-brake release
delay
0.0s
~
25.0s
0.1s
1.0s
Run&Stop
070DH
P18.07
Post-brake release
delay
0.0s
~
25.0s
0.1s
1.0s
Run&Stop
070EH
P18.08 Brake logic indicator
0: Apply
1: Release
1
Actual
Actual
070FH