![Veikong VFD700 Series Скачать руководство пользователя страница 118](http://html1.mh-extra.com/html/veikong/vfd700-series/vfd700-series_operation-manual_3864500118.webp)
Appendix
VFD700 AC Drive Getting Started Guide
111
Menu P06: V/Fcontrols parameters
ID
Function
Range
Step
Default
Change
Mode
Modbus
Register
Address
P06.01 V/F control mode
0: User
programmed V/F
ramp
1: 2 law ramp
2: 1.7 law ramp
3: 1.2 law ramp
1
0
Stop Only
0258H
P06.02 V/F frequency 3
(P06.04)
~
(P13.08) 0.01Hz
0.00Hz
Stop Only
0259H
P06.03 V/F voltage3
(P06.05)
~
100.0%
(refer to motor
rated voltage)
0.1%
0.0%
Stop Only
025AH
P06.04 V/F frequency 2
(P06.06)
~
(P06.02) 0.01Hz
0.00Hz
Stop Only
025BH
P06.05 V/F voltage 2
(P06.07)
~
(P06.03)
0.1%
0.0%
Stop Only
025CH
P06.06 V/F frequency 1
0.00
~
(P06.04)
0.01Hz
0.00Hz
Stop Only
025DH
P06.07 V/F voltage 1
0
~
(P06.05)
0.1%
0.0%
Stop Only
025EH
P06.08 Voltage boost
0.0%
~
30.0%
(refer to motor
rated voltage)
0.1%
By model
Run&Stop
025FH
P06.09
Boost finish
frequency
0.0%
~
50.0%
(refer to motor
rated voltage)
0.1%
50.0%
Run&Stop
0260H
P06.10
Stable factor
control
0: Off
1: On
1
0
Run&Stop
0261H
P06.11
Auto energy
saving control
0: Off
1: On
1
0
Stop Only
0262H
P06.12 AVR control
0: Off
1: On for all
condition
2: On except ramp
1
1
Stop Only
0263H
NOTE: (Pxx.xx) means the value of Pxx.xx.