![Veikong VFD700 Series Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/veikong/vfd700-series/vfd700-series_operation-manual_3864500061.webp)
3 Operation and display
54VFD700 AC Drive Getting Started Guide
3.2.4 Priority of running mode
Under speed mode, VFD700 has 4 running modes, the priority level from high to low is as:
Jog >PLC >Textile>Common running, showed in figure 3-10:
High priority
Low priority
Stop status
Power on
Speed control
mode
YES
YES
YES
Textile
running
PLC
running
Jog
running
Common
running
NO
NO
PLC valid
P04.17
≠
0?
Textile valid
P14.01
≠
0?
Jog order?
NO
Figure 3-10 VFD700 Running mode Priority
3.3 Quick commissioning
3.3.1Keypad control
Use the parameter menu0 to explain the drive setup as below.
Table 3-4 Keypad control setup
Parameter Setup
Description
P00.13=motor nameplate data
Set the motor rated voltage
P00.14=motor nameplate data
Set the motor rated current
P00.15=motor nameplate data
Set the motor rated frequency
P00.16=motor nameplate data
Set the motor rated speed
P00.19=motor nameplate data
Set the Power factor of the motor
Other parameters are default setup.