9 Door Expander
The two door expander can handle up to two doors and two card readers. Configuration of the operation
mode is done via the two door I/Os. Each of the two door I/Os is responsible for the functionality of two
inputs and one output of the door controller. A specific door number can be assigned to a door I/O, which
gives the inputs and output predefined functionality. If no door number is assigned to neither of the door
I/Os (option “Zones” is selected), the inputs and outputs of the door controller can be used like inputs and
outputs on the control panel. Thus, no access functionality is available on this two door controller.
If a door number is assigned only to the first door I/O of the two door controller, the first reader is used as
entry reader for this door. If a second reader is available, it is used as exit reader for the configured door.
Two inputs and one output have predefined functionality and two inputs and one output can be configured
by the user. Additionally, the door position sensor input of the first door can be used as intrusion zone but
only with limited functionality.
If a door number is assigned to each of the two door I/Os, the two doors are handled independently. The
first card reader is used as entry reader for the first door and the second card reader is used as entry reader
for the second door. All inputs and outputs have predefined functionality. The door position sensor inputs of
the two doors can additionally be used as intrusion zones but only with limited functionality.
See
Supported card readers and card formats
on page 388 for details of currently supported card readers
and card formats.
Each free zone number can be assigned to the zones. But the assignment is not fixed. If number 9
was assigned to a zone, the zone and an input expander with the address 1 is connected to the X-Bus
(which is using the zone numbers 9–16).The assigned zone from the two door controller will be moved
to the next free zone number. Configuration will be adapted accordingly.
© Vanderbilt 2018
74