RF FOB
SOS
Select how the SOS buttons on the RF Fob should operate.:
l
Disable
l
Enable
l
Enabled Silent
l
User Medic
l
User Holdup
l
RF Output
WPA Test
Schedule
1
Enter a maximum period (in days) between WPA tests.
Prevent
Setting
Time
Enter a time in minutes after which, if the sensor fails to report, a setting is prevented for an area
where the wireless zone is.
This setting applies to the following intrusion zones only:
l
Alarm
l
Entry/Exit
l
Exit Term
l
Panic
l
Hold up
l
Tamper
l
Lock Supervision
l
Seismic
l
All OK
l
Setting Authorisation
l
Lock Element
Device Lost
Time
Enter a number of minutes after which the wireless device (sensor or WPA) device is reported as
lost.
1
A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.
For CE regulatory compliance, the SPCW120 product is to be fitted to the following products only:
l
SPC5330.320-L1
l
SPC6330.320-L1
l
SPC4320.320-L1
l
SPC5320.320-L1
l
SPC5350.320-L1
l
SPC6350.320-L1
17.10 Configuration
This section covers:
17.10.1 Configuring controller inputs and outputs
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
228
A6V10276959-d
11.2018