Attribute
Description
Custodian*
The custodian feature allows a card holder with custodian right (the custodian) to give other
cardholders (non-custodians) access to the room.
The custodian must be the first to enter the room. The non-custodians are only allowed to enter if
the custodian is in the room. The custodian will not be allowed to exit until all non-custodians have
left the room.
Door
Sounder
Door controller PCB mounted sounder sounds on door alarms.
Ignore
Forced
Door forced open is not processed.
Interlock*
(Browser)
Only one door in an area will be allowed open at a time. Requires Door Group.
Setting
Prefix
Authorisation with prefix (A,B,* or #) key to set system
* Require door group
Door timers
Timer
Min.
Max.
Description
Access
granted
1 s
255 s
The time the lock will remain open after granting access.
Access
deny
1 s
255 s
The duration after which the controller will be ready to read the next event after a
invalid event.
Door open
1 s
255 s
Duration within which the door must be closed to prevent a “door open too long”
alarm.
Door left
open
1
min
180
min
Duration within which the door must be closed to prevent a “door left open” alarm.
Extended
1 s
255 s
Additional time after granting access to a card with extended time attribute.
Escort
1 s
30 s
Time period after presenting a card with escort attribute within a user without
escort right can access the door.
16.12 Outputs
Each zone type on the SPC system has an associated output type (an internal flag or indicator). When
a zone type is activated, that is, a door or window opens, smoke is detected, an alarm is detected, etc.,
the corresponding output is activated.
1. Scroll to OUTPUTS and press SELECT.
2. Scroll to CONTROLLER or EXPANDER and press SELECT.
3. Scroll to the expander/output to be programmed and press SELECT.
If the output activations are recorded in the system event log (that is, enabled, items
recorded/disabled, items) the programming options are available as shown in the table below.
NAMES
Used to help identify the output; enter a specific and descriptive name.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the keypad