Wireless
Lost Event
Click to send Wireless Lost event over CID/SIA and FlexC.
Supervision
Set the amount of time in minutes between occurrences of two way wireless signal supervision.
Antenna
Select the type of antenna connected to the wireless module (internal or external) from the drop
down menu. The type of antenna required for the wireless module depends on the type of
wireless module fitted.
Missing
Supervision
Select whether a wireless sensor that is reported as missing registers a tamper condition on the
signet panel.
A wireless sensor is reported as missing when no supervision signal has been received from the
sensor for a period greater than the programmed Wireless Lost timer. See
RF FOB
SOS
Select how the SOS buttons on the RF Fob should operate.:
l
Disable
l
Enable
l
Enabled Silent
l
User Medic
l
User Holdup
l
RF Output
WPA Test
Schedule
1
Enter a maximum period (in days) between WPA tests.
Prevent
Setting
Time
Enter a time in minutes after which, if the sensor fails to report, a setting is prevented for an area
where the wireless zone is.
This setting applies to the following intrusion zones only:
l
Alarm
l
Entry/Exit
l
Exit Term
l
Panic
l
Hold up
l
Tamper
l
Lock Supervision
l
Seismic
l
All OK
l
Setting Authorisation
l
Lock Element
Device Lost
Time
Enter a number of minutes after which the wireless device (sensor or WPA) device is reported
as lost.
1
A WPA is compatible with SiWay RF Kit (SPCW110, 111, 112, 114 ) only.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
219
A6V10276959-d
11.2018