Number Name
Description
11
Zone inputs
The controller provides 8 on-board zone inputs that can be monitored using a variety of
supervision configurations. These configurations can be programmed from system
programming. The default configuration is Dual End of Line (DEOL) using resistor values
of 4k7. See
12
Tamper
terminals
The controller provides 2 additional tamper input terminals that can be connected to
auxiliary tamper devices to provide increased tamper protection. These terminals should
be shorted when not in use.
13
Serial port 2
terminal
block
Serial port 2 terminal block (TX, RX, GND) may be used to interface to an external
modem or PC terminal program. Serial port 2 shares a communications channel with the
back-up modem. If a back-up modem is installed, ensure that no devices are connected
to this serial port.
14
Ethernet
connectivity
LEDs
The 2 Ethernet LEDs indicate the status of the Ethernet connection. The left LED
indicates data activity on the Ethernet port; the right LED indicates the Ethernet link is
active.
15
Ethernet
interface
The Ethernet interface provides for the connection of a PC to the controller for the
purposes of programming the system.
16
USB
interface
This USB interface is used to access browser programming or a terminal program.
17
Serial port 2
This RS232 serial port may be used to interface to an external modem or PC terminal
program. Serial port 2 shares a communications channel with the back-up modem. If a
back-up modem is installed, ensure no devices are connected to this serial port.
18
Serial port 1
This RS232 serial port may be used to interface to an X10 protocol device.
19
Optional
plug-in
modules
A primary (left slot) and back-up (right slot) module can be connected to the controller.
These modules can be GSM or PSTN modems offering increased communication
functionality. The back-up modem should not be connected if serial port 2 interface is
connected to an external modem or other device.
20
Front
tamper
This on-board front tamper (switch and switch) provides the housing tamper protection.
Note:
The front tamper is not used in the G5 housing.
21
Battery
selector
J12: Fit jumper for 17Ah battery use and remove for 7Ah battery.
Please Note: This selector is only available on 2.3 revision controller PCB.
(Not applicable for SPC5350 and SPC5360 panels.)
22
Auxiliary
power input
12V input from battery or PSU**.
* Default setup for SPC5350 and SPC5360 panels
** PSU only applies to SPC5350 and SPC6350 panels.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Controller hardware