Status
The programmed status of that zone. A status value of Normal means that the zone is
programmed to operate normally. The following is a complete list of possible values:
Isolate, Soak, Inhibit, Tamper, Alarm, Fire Exit, Warning Fault, Holdup Fault, Detector Fault, Line
Fault, Panic, Hold Up, Tech, Medic, Lock, Fire, Trouble, PIR Masked, Normal, Actuated,
Tamper, Post Alarm. A zone is in the post alarm status if an alarm occurred and the confirmed
alarm timed out. This reinstates the zone, however it also flags that an alarm did occur.
Performable actions
Refresh
Updates the status information displayed for the panel.
Log
Click the
Log
button to view a log of the input status of that zone.
Inhibit
Click this button to inhibit a fault or open zone. The inhibit operation will disable that fault or zone for one
arming period only.
Inhibit operation is not available in Security Grade EN 50131 Grade 3.
Restore
Click this button to restore the alarm condition of the panel.
Isolate
Zone . Isolating a zone will deactivate that zone until such time as the zone is explicitly deisolated
again.
It is recommended that you exercise caution when isolating zones as those zones will not be active
every time the system is SET.
Soak
Highlight a zone and click this button to perform a Soak test on that zone.
Seismic
Test
Click this button to initiate a test of the selected seismic sensor. For more information on seismic
sensors, see
Hide
Closed
Click this button to hide all closed inputs.
Filter
Zones
Select a zone type from the dropdown menu. Only the summary of this zone type will be displayed.
17.6.5 Doors
1. Select
Status > Doors
.
See tables below for further information.
Door
This ID number is a unique identifier for the door.
Zone
The zone number the door position sensor is attached to (only if the door position sensor input is also
used as intrusion zone).
Area
The area the door position sensor input and the card reader are assigned to.
DPS
Status of the door position sensor.
DRS
Status of the door release switch.
Status
The status of the door (OK, fault).
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
191
A6V10276959-d