The following types are displayed in this log:
l
Zones
– Alarm
– Panic
l
System Events
– Confirmed Alarm
– User Duress
– XBus Panic
– User Panic
– RPA Panic
17.8 Users
The following table shows the maximum number of users, user profiles and user devices for the panel:
Maximum No.
SPC4xxx
SPC5xxx
SPC6xxx
Users
100
500
2500
User Profiles
100
100
100
User Profiles per User
5
5
5
PACE Devices
32
250
250
SMS IDs
32
50
100
Web Passwords
32
50
100
RF Fobs
32
50
100
MDT Devices
32
32
32
WARNING: If upgrading from a firmware version prior to version 3.3, note the following:
- The Engineer web password, if configured, is deleted and must be reentered after upgrade.
- All existing users will be assigned to new user profiles corresponding to their previous user
access levels. If max. number of user profiles is exceeded, no profile is assigned (see
on page 199). Review all user configuration after a firmware upgrade.
- The default Engineer ID is changed from 513 to 9999.
17.8.1 Adding/Editing a User
To add or edit a user:
1. Select
Users>Users
.
A list of configured users is displayed.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
196
A6V10276959-d
11.2018