Restriction
System
Option
Description
PIN Policy
Click the
Edit
button to select options for PIN usage.
l
Periodic changes required – enforces scheduled changes to the user’s
PIN. The period is defined in the
PIN Valid
field of
Timers
. See
l
Warn if changes required – generates a user alert if the user’s PIN is about
to expire, or has expired. The warning period is defined in the
PIN
Warning
field of
Timers
. See
l
User selects the last digit – enables the user to select the last digit of their
pin. The preceding digits are automatically generated by the system.
l
User selects the 2 digits - enables the user to select the last two digits of
their PIN. The preceding digits are automatically generated by the system.
l
Limit Changes – limits the number of changes possible within a valid PIN
period. This value is defined in the
PIN Changes Limit
field of
Timers
.
See
l
Secure PIN - If enabled the PIN will be automatically generated by the
panel.
Door & Reader
Reset Cards
If enabled, access cards passback state will be reset every day at midnight.
Ignore site code If enabled, the access system will ignore site codes. By ignoring the site code,
you only add the card number and increase the card users on the system from
100 to 2,500.
Card Formats
Click the
Edit
button to select the card formats that will be allowed on this
panel.
See
Supported card readers and card formats
on page 388 for details of
currently supported card readers and card formats.
Note:
Selecting
Wiegand
enables all Wiegand card formats.
Web Only
Door Mode Set
Select the required user identification to unlock door when area is set. Options
are
Default
,
Card and PIN
,
Card Or PIN
.
Web Only
Door Mode
Unset
Select the required user identification to unlock door when area is unset.
Options are
Default
,
Card and PIN
,
Card Or PIN
.
Override
Reader Profile
If enabled, Reader LEDs indicate setting confirmation and Card+PIN request.
Engineer
Engineer
Restore
(Impact only if Region "UK" is chosen): If this option is enabled, then the
engineer has to restore the confirmed alarms. This option works together with
the function "Confirmation".
Engineer Exit
If enabled, the engineer is allowed to leave Full Engineer mode with alerts
active.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
259
A6V10276959-d
11.2018