2. Configure the fields as described in the table below.
Enable
Tick this checkbox to enable EDP operation on the system.
EDP
Panel ID
Enter a numeric identifier that is used by the EDP Receiver to identify the panel
uniquely.
Panel
Port
Select the IP port for receiving IP packets. Default is 50000.
Packet
Size
Limit
Enter the maximum number of bytes in an EDP packet for transmission.
Event
timeout
Enter the timeout period (in seconds) between retransmissions of
unacknowledged events.
Retry
Count
Enter the maximum number or event retransmissions allowed by the system.
Dial
Attempts
Enter the maximum number of failed dial attempts accepted by the system
before the modem is locked out (prevented from making further attempts to dial).
The lockout period is defined in the option Dial Lockout.
Dial
Delay
Enter the time period (in seconds) that the system will wait before redialling after
a dial attempt has failed.
Dial
Lockout
Enter the time period (in seconds) that the system will suspend dialling when the
maximum number of failed dial attempts is reached. Enter a value of ‘0’ to
continually attempt dialling.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
334
A6V10276959-d
11.2018