23.19 ATS levels and attenuation specifications
ATS (Alarm Transmission System) Levels
The following table lists the ATS levels required for the panel when communicating over:
l
GSM to Alarm Reporting Centre (ARC)
l
PSTN to Alarm Reporting Centre (ARC)
l
Ethernet to SPC Comm receiver software
l
GPRS to SPC Comm receiver software
GSM ARC
PSTN ARC
Ethernet
GPRS
ATS Level
ATS 2
ATS 2
ATS 6
ATS 5
Attenuation of PSTN
For a PSTN dialer, a CW1308 Internal Telecom or equivalent cable should be used to connect the modem
to the phone line. The cable length should be between 0.5–100m.
Attenuation of Ethernet
For Ethernet, a Cat 5 cable should be used with its length between 0.5–100m.
Attenuation of GSM
The field strength of the GSM signal needs to at least -95dB. Below this level the modem will flag a low
signal fault to the panel. This is handled in the same way as other faults on the system.
Monitoring and watchdog of PSTN (SPCN110) and GSM (SPCN320)
A failure of the interface between the PSTN modem and the panel will be detected after 30 seconds, after
which an ATS fault will occur.
A failure of the interface between the GSM modem and the panel will be detected after 30 seconds, after
which an ATS fault will occur.
23.20 Supported card readers and card formats
The following card readers and formats are supported on the SPC system:
Reader
Card Format
HD500-EM
PR500-EM
SP500-EM
PM500-EM
IB41-EM
IB42-EM
IB44-EM
IB45-EM
ABR5100-BL
ABR5100-TG
ABR5100-PR
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Appendix
© Vanderbilt 2018
388
A6V10276959-d
11.2018
Содержание SPC4 Series
Страница 1: ...SPC4xxx 5xxx 6xxx Installation Configuration Manual Document ID A6V10276959 d Edition date 11 2018 ...
Страница 400: ...24 Notes Vanderbilt 2018 400 A6V10276959 d 11 2018 ...
Страница 401: ...SPC4xxx 5xxx 6xxx Installation Configuration Manual Vanderbilt 2018 401 A6V10276959 d 11 2018 ...