4 Technical Data
This chapter covers:
4.1 SPC4000
Programmable areas
4
Max. number of user PINs
100
Remote controls
Up to 32
PACE Devices
32
Wireless Panic Alarm
Up to 128
Event memory
1000 intrusion events, 1000 access events
Number of on-board zones
8
Max. number of hardwired zones
32
Max. number of wireless zones
32 (take away wired zones)
Max. number of Intrunet wireless
detectors per wireless receiver
(recommended)
20
EOL resistor
Dual 4k7 (default), other resistor combinations configurable
Number of on-board relays
1 strobe (30V DC/1A resistive switching current)
Number of on-board open coll.
2 internal/external bell, 3 freely programmable (each max. 400mA resistive
switching current, supplied via auxiliary output)
Firmware
V3.x
Door capacity
Max. 4 entry doors or 2 entry/exit doors
Number of card reader
Max. 4
Radio module
l
SPC4221: integrated SiWay RF receiver (868MHz)
l
SPC4320.220: Optional (SPCW111)
l
SPC4320.320: Optional (SPCW110)
Verification
4 verification zones with max. 4 IP-cameras and 4 audio devices.
Video
Up to 16 pre/16 post event images (by JPEG resolution 320 x 240, max. 1
frame/sec.)
© Vanderbilt 2018
31
A6V10276959-d
11.2018
Содержание SPC4 Series
Страница 1: ...SPC4xxx 5xxx 6xxx Installation Configuration Manual Document ID A6V10276959 d Edition date 11 2018 ...
Страница 400: ...24 Notes Vanderbilt 2018 400 A6V10276959 d 11 2018 ...