1. Select
Configuration > Areas > Areas
.
The following page will be displayed:
2. Click
Edit
to edit an existing area.
3. Click
Add
to add a new area. If the Installation Type is
Domestic
or
Commercial
, an area is
automatically added and the
Edit Area Settings
page is displayed.
Note that the area type for the new area is automatically set to Standard.
If the Installation Type is
Financial
, the following page is displayed and the area must be added
manually.
4. Enter a description for the new area and select an area type from one of the following:
- Standard – Suitable for most areas.
- ATM – Provides settings and defaults relevant to ATMs.
- Vault – Provides settings and defaults relevant to vaults.
- Advanced – Provides all area settings (Standard, ATM and Vault).
5. Click the
Add
button to add the area.
Configure the settings for each installation type as per the following sections.
Entry/Exit
Configure the following Entry/Exit settings:
Entry time
The time period (in seconds) allowed for the user to UNSET the alarm after opening an entry/exit
zone of an armed system. The entry time applies to all entry/exit zones in that area (default: 45
seconds).
Exit time
The time (in seconds) allowed for a user to leave a protected area before setting is complete. The
exit time will be counted down at the keypad as the buzzer beeps to indicate to the user that the
system will arm when the exit timer reaches zero. The exit time applies to all entry/exit zones in
that area (default: 45 seconds).
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Engineer programming via the browser
© Vanderbilt 2018
271
A6V10276959-d
11.2018
Содержание SPC4 Series
Страница 1: ...SPC4xxx 5xxx 6xxx Installation Configuration Manual Document ID A6V10276959 d Edition date 11 2018 ...
Страница 400: ...24 Notes Vanderbilt 2018 400 A6V10276959 d 11 2018 ...
Страница 401: ...SPC4xxx 5xxx 6xxx Installation Configuration Manual Vanderbilt 2018 401 A6V10276959 d 11 2018 ...