NOTICE: Vanderbilt recommends you read the
Sintony System Migration
document before
configuring E-Bus devices.
23.21.1 Configuring and Addressing E-Bus Devices
You can configure and address the following Sintony E-Bus devices to communicate with the SPC
controller:
l
Sintony keypads SAK41/SMK41, SAK51/SMK51, and SAK53/SMK53
l
Sintony input transponders
l
Sintony output transponders
l
Sintony PSUs: SAP 8, SAP 14, SAP 20, and SAP 25
1. In the browser, go to
Settings > X-BUS > Expanders
.
A list of
Configured Expanders
displays.
2. Select an
SPC E-Bus Gateway
.
3. On the
Expander Configuration
page, enter a
Description
for the
SPC E-Bus Gateway
. For
more information on configuring expanders, see
4. To address an E-Bus device, select an ID from the relevant dropdown menu described in the
table below. An asterisk (*) prefixes an ID that is in use. You cannot select this ID.
5. Click the
Select
button.
Address in progress.....Reconfiguration of Xbus will be required
displays at the top of the page.
The SPC E-Bus Gateway beeps repeatedly.
6. Depending on the E-Bus device, hold the addressing button as described in the
Addressing
column in the table below.
The SPC E-Bus Gateway beeps continuously to indicate the ID is now associated with the E-
Bus device.
7. Go to
Settings > X-BUS > Expanders
.
8. Click the
Reconfigure
button.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Appendix
© Vanderbilt 2018
391
A6V10276959-d
11.2018