Key
VR 32
VR 32 bus coupler
VR 60
VR 60 mixer module
BUS eBUS
WW DHW
cylinder
ZIR Circulation
pump
SP
Cylinder sensor
KW
Cold water
VF 1
Flow temperature sensor
VF 2
Flow temperature sensor, Heating circuit 2
VF 3
Flow temperature sensor, Heating circuit 3
VFa
Flow temperature sensor, Mixer circuit a
VFb
Flow temperature sensor, Mixer circuit b
HK 1-P
Pump for direct circuit
HK 2-P Pump for heating circuit 2
HK 3-P Pump for heating circuit 3
HKa-P
Heating pump for mixer circuit
HKb-P
Heating pump for mixer circuit
HK 2
Mixer for heating circuit 2
HK 3
Mixer for heating circuit 3
HK a
Mixer for mixer circuit a
HK b
Mixer for mixer circuit b
LP/UV1 cylinder charging pump/Diverter valve
i
Caution - illustration shows principle only!
This system schematic does not include all
the shut-off and safety devices necessary for
professional assembly. System-specific plan-
ning is required!
5.4 Connecting
the
DCF receiver
b
Caution!
Malfunctions caused by incorrect
installation!
Any external sensor connected to the boiler
will be ignored.
Connect the external sensor to the control-
ler.
Abb. 5.11 Connecting the DCF receiver
left: with the external sensor (VRC DCF) supplied,
right: special solution with the VRC 693 external sen-
sor
If no radio signal can be received at the location where
the external sensor is installed, a solution using the
VRC 693 external sensor is required.
Connect the external sensor to the controller.
Wire the DCF receiver as shown in Fig. 5.11.
If you have fitted the VRC DCF external sensor, note
that:
Normally, the synchronisation time for radio recep-
tion is approx. 5 minutes but, depending on the
local and structural conditions as well as the wea-
ther, can take up to 20 minutes.
>
>
>
–
41
Installation Instructions VRC 630 0020095108_00
Electrical installation 5