4.8.2 Installing the controller as a remote control
device
If you want to mount the controller on the wall as a
remote control unit with thermostatic control, take note
of the following:
Required accessory:
You will need the VR 55 wall mounting box (acces-
sory, not included in kit). A cover for the wall mount
is supplied together with the VR 55 mounting box.
Installation location
:
The best place for installation is usually in the main
living room on an inside wall at a height of approx. 1.5
m.
Mount the controller so that it can sample the circula-
ting room air, unhindered by furniture, curtains or
other objects.
Choose a location where the room thermostat is not
affected by draughts from doors or windows, or by
heat sources such as radiators, chimney walls, televi-
sion sets or direct sunlight.
i
All radiator valves must be fully open in the
room in which the remote control device is
installed if room thermostat control is activa-
ted. Point this out to the owner.
e
Danger!
Danger to life from live connections!
The mains switch does not disconnect the
power supply completely.
Switch the power supply off before wor-
king on the unit.
Secure the power supply against being
switched on again.
Lay the electrical lines up to the boiler expediently
before installing the controller.
–
–
>
>
>
>
>
3
1
4
2
Fig. 4.4 Installation as a remote control device
Key
1 Controller
2 Receptacles
3 Cable
feedthrough
4 Mounting
holes
Switch off the power.
Secure the power supply against being switched on
again.
Open the wall mount using a screwdriver.
Remove the housing cover.
Take out the controller.
Drill two 6 mm fixing holes (
3
) for the VR 55 moun-
ting box (
¬ Fig. 4.4
).
Insert the wall plugs supplied.
Pass the connecting cable through the duct (
3
).
Attach the mounting box to the wall with the two
screws provided.
Connect the connecting cable (
¬ Fig. 4.3
).
Place the controller on the mounting box so that the
pins on the back of the top part fit into the receptac-
les (
2
).
Push the controller (
1
) on to the mounting box until it
engages.
Insert the supplied cover in the wall mount.
Fit the cover.
>
>
>
>
>
>
>
>
>
>
>
>
>
>
23
Installation Instructions VRC 630 0020095108_00
Assembly 4
Содержание VRC 630
Страница 1: ...GB VRC 630 3 ...
Страница 2: ......
Страница 54: ......
Страница 55: ...For the heating engineer Installation Manual VRC 630 ...
Страница 145: ...91 Installation Instructions VRC 630 0020095108_00 Appendix Declaration of conformity Fig A 1 Declaration of conformity ...
Страница 152: ...0020095108_00 GB 022010 Subject to alterations ...