Operation 5
Operating manual VRC 630 0020095108_00
31
HK1
5
Parameters
Night set back temp
16°C
Heating curve
1.2
>Select target room temperature
Turn the right hand dial until the desired
Night set
back temperature
is displayed.
i
If necessary, find out about the optimum set-
ting from your heating engineer.
HK1
5
Parameters
Night set back temp
16°C
Heating curve
1.2
>Select target room temperature
Press the right hand dial.
The
Night set back temperature
is saved.
Always observe the information on frost protection
(
¬ Chap. 5.12
).
5.6.2 Setting the heating curve
Your selection of heating curve will influence the flow
temperature of your heating
.
b
Caution!
Material damage caused by high flow tem-
peratures with underfloor heating!
Flow temperatures above 40 °C can cause
material damage with underfloor heating.
Do not set the flow temperature above
40 °C if underfloor heating is in use.
The heating curve shows the relationship between the
outside temperature and the flow temperature. The set-
ting is made separately for each heating circuit
(
¬ Chap. 3.5
).
The room temperature of your heating installation
depends to a great extent on the selection of the right
heating curve. If the selected heating curve is too high,
the temperatures in the heating installation will also be
too high, resulting in higher energy consumption.
If the selected heating curve is too low, the desired tem-
perature level may only be reached after a while or not
reached at all.
>
>
>
>
HK1
5
Parameters
Night set back temp
16°C
Heating curve
1.2
> Select heating curve
Turn the right hand dial until the cursor
is flashing
in front of the
Heating curve
.
HK1
5
Parameters
Night set back temp
16°C
Heating curve
1.2
> Select heating curve
Press the right hand dial.
The
Heating curve
is marked.
HK1
5
Parameters
Night set back temp
16°C
Heating curve
1.1
> Select heating curve
Turn the right hand dial until the desired
heating
curve
is displayed.
HK1
5
Parameters
Night set back temp
16°C
Heating curve
1.1
> Select heating curve
Press the right hand dial.
The
heating curve
is saved.
After an extended period without any operations, the
display automatically reverts to the basic display.
>
>
>
>