58
Installation Instructions VRC 630 0020095108_00
7 Operating the controller
7.3.1
Menu C2: Setting the parameters for HK1...
HK15
b
Caution!
Material damage caused by high flow tem-
peratures with underfloor heating!
Flow temperatures above 40 °C can cause
material damage with underfloor heating.
Do not set the flow temperature above
40 °C if underfloor heating is in use.
The parameters for each heating circuit are set in
Menu
C2
.
A maximum of 15 heating circuits can be configured for
the heating installation.
All connected heating circuits can be configured in the
Installation Assistant (
¬
Menu
A6
) according to how
they are used. Due to the configuration, only those
values and parameters which are relevant to the
selected type of use for the heating circuit are dis-
played.
Types of use for:
HK1
Direct circuit/disabled
Mixer circuits
Direct/mixer circuit (underfloor or radiator circuit as
mixer circuit)
Fixed value(i.e. the mixer circuit is controlled at a
fixed value)
Return flow boost (for conventional heating appli-
ances and systems with a large water content as pro-
tection against corrosion in the heating boiler caused
by prolonged periods below the dew point).
Cylinder charging circuit
Disabled, if a heating circuit is not required, so that:
the parameters in the display are blanked
no target flow temperature is calculated for the
circuit.
Cylinder
Cylinder charging circuit/disabled
>
–
–
–
–
–
–
–
–
–
Examples of Menu
C2
HK1
C2
Parameters
Type: Direct cir-
cuit
Set-back temperature
15 °C
Heating curve
1,2
Max limit outs.temp.
21°C
>Select target room temperature
HK2 ... HK15
C2
Parameters
Type: Fixed value
Fixed value day
65 °C
Fixed value night
65 °C
Max limit outs.temp.
20°C
>Select target room temperature
HK2 ... HK15
C2
Parameters
Type: Mixer circuit
Set-back temperature
15 °C
Heating curve
0,90
Max limit outs.temp.
20°C
>Select target room temperature
HK2 ... HK15
C2
Parameters
Type: Cylinder charging
circuit
Cylinder ACT
56°C
Status load pump
Off
HK2 ... HK15
C2
Parameters
Type: ret.temp
incr.
Return temperature
30°C
Return temperature
ACT
25°C
> Select return temperature
Many parameters are held in Menu
C2
. They cannot all
be displayed on a single screen.
Turn the left hand knob to display more parameters.
>