Commands
TF
infinite, never expires (factory default)
I0
input inversion disabled (factory default)
I1
input inversion enabled
For example, if factory default settings are assigned, the reader message is:
PRST P0 D0 A2 TF I0
Presence without tag reports disabled, minimum presence true period is 0, RF-off
control on timeout or presence false, infinite RF timeout, and input inversion
disabled
530 Display RF0 Filter Status
Command 530 displays the parameter set for the RF channel input, including the
selected unique ID code criteria (command 410N) and the valid ID code criteria,
which are fixed at one acquisition.
Reader message:
RF0S U<0-3> V0
where
U0
one ID separation (factory default)
U1
two ID separation
U2
transmit all IDs
U3
buffer all IDs
V0
valid ID code criteria of one acquisition (fixed)
For example, if factory default settings are assigned, the reader message is:
RF0S U0 V0
Separation of one ID for uniqueness filtering and a valid ID code criteria of one
acquisition
532 Display Wiegand Mode Status
Command 532 displays Wiegand mode status enabled or disabled.
Reader message:
TOF <0-1>
where
0
Wiegand mode disabled
1
Wiegand mode enabled
533 Display Wiegand Retransmit Interval
Command 533 displays the Wiegand retransmit interval. This interval specifies the
delay (in seconds) before the reader will retransmit Wiegand data for a tag still in the
read zone. The factory default is 1 second.
9-33
Содержание SmartPass AI1611
Страница 4: ......
Страница 17: ...A Glossary...
Страница 18: ......
Страница 22: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide A 6...
Страница 23: ...B System Specifications...
Страница 24: ......
Страница 26: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide B 4...
Страница 27: ...C Wiring Tables...
Страница 28: ......
Страница 32: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide C 6...
Страница 33: ...1 Introduction...
Страница 34: ......
Страница 40: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 1 8...
Страница 41: ...2 Preparing the Site...
Страница 42: ......
Страница 52: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 2 12...
Страница 53: ...3 Quick SmartPass Test...
Страница 54: ......
Страница 63: ...4 Installing Tags on Vehicles...
Страница 64: ......
Страница 71: ...5 Installing SmartPass...
Страница 72: ......
Страница 90: ...6 General Software Information...
Страница 91: ......
Страница 99: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 6 10...
Страница 100: ...7 Modes of Operation...
Страница 101: ......
Страница 106: ...8 Communication Protocols...
Страница 107: ......
Страница 124: ...9 Commands...
Страница 125: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 9 2...
Страница 174: ...10 Troubleshooting...
Страница 175: ......
Страница 179: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 10 6...