SmartPass® Integrated Reader 2450 MHz (High Voltage) System Guide
Note:
In the following table:
•
Items in
bold italics
identify factory default settings.
•
Only the data portion of the command number is shown.
•
Only the command-related data portion of the reader message is shown.
•
Refer to Chapter 8, “Communication Protocols,” for the complete syntax of
commands and messages.
Table 9-3 SmartPass Command List (Ordered by Command Name)
Command name
Code
Reader Message
All IDs Transmit
40
Done
Appended info status Display
524
IDAP Tx Dx Xx
T0 = time not appended
T1 = time appended
D0 = date not appended
D1 = date appended
X0 = aux info not appended
X1 = aux info appended
Aux info append Disable
310
Done or Error
Aux info append Enable
311
Done or Error
Basic protocol Select
610
Done or Error
Baud rate = 110 baud Set
1000
Done or Error
Baud rate = 1200 baud Set
1002
Done or Error
Baud rate = 19.2 K baud Set
1006
Done or Error
Baud rate = 2400 baud Set
1003
Done or Error
Baud rate = 300 baud Set
1001
Done or Error
Baud rate = 4800 baud Set
1004
Done or Error
Baud rate = 9600 baud Set
1005
Done or Error
Boot checksum Display
543
BCKS xxxx
xxxx = 4-byte ASCII checksum
Boot ROM checksum Verify
667
Done or Error
Buffer all IDs
43
Done
Buffer control mode Disable
6160
Done
Buffer control mode Enable
6161
Done
Buffer control status Display
535
BCM x
0 = disabled
1 = enabled
Buffer entry Transmit
06
Done, Error, or Tag Data
Done = buffer empty
Error = not in buffer control mode
Tag Data = highest priority tag ID
Check tag Select External
8161
Done
Check tag Select Internal
8160
Done
Check tag Invoke
8110
Done
9-12
Содержание SmartPass AI1611
Страница 4: ......
Страница 17: ...A Glossary...
Страница 18: ......
Страница 22: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide A 6...
Страница 23: ...B System Specifications...
Страница 24: ......
Страница 26: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide B 4...
Страница 27: ...C Wiring Tables...
Страница 28: ......
Страница 32: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide C 6...
Страница 33: ...1 Introduction...
Страница 34: ......
Страница 40: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 1 8...
Страница 41: ...2 Preparing the Site...
Страница 42: ......
Страница 52: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 2 12...
Страница 53: ...3 Quick SmartPass Test...
Страница 54: ......
Страница 63: ...4 Installing Tags on Vehicles...
Страница 64: ......
Страница 71: ...5 Installing SmartPass...
Страница 72: ......
Страница 90: ...6 General Software Information...
Страница 91: ......
Страница 99: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 6 10...
Страница 100: ...7 Modes of Operation...
Страница 101: ......
Страница 106: ...8 Communication Protocols...
Страница 107: ......
Страница 124: ...9 Commands...
Страница 125: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 9 2...
Страница 174: ...10 Troubleshooting...
Страница 175: ......
Страница 179: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 10 6...