JUNE 2002 © TOSHIBA TEC
2 - 19
e-STUDIO550/650/810 ERROR CODES AND SELF-DIAGNOSIS
<Operation procedure>
Notes: 1. An error code is displayed on the control panel if an error occurs in the process, but no recovery
operation is performed.
2. Turn the power OFF, and then turn it back ON to clear the error.
Code
Types of test pattern
Remarks
111
Primary scanning direction, 33 gradation steps, error diffusion
113
Secondary scanning direction, 33 gradation steps, error diffusion
142
Grid pattern (Pattern width: 2 dots, Pitch: 10 mm)
[0] [4]
[POWER]
(Code)
[START]
[POWER]
OFF/ON
(Exit)
Operation
(Test print)
[CLEAR]
2. 2. 3. Test print mode (test 04)
The built-in test pattern can be printed out by entering the following codes in the test print mode (04).