JUNE 2002 © TOSHIBA TEC
3 - 39
e-STUDIO550/650/810 ADJUSTMENT
3. 11. Adjustment of Reversing Automatic Document Feeder
3. 11. 1. Installing of the RADF unit
When replacing an RADF unit to another one, install it with 2 RADF positioning pins according to the
following procedure.
(1) Attach the positioning pins to the copier.
(2) Put the RADF quietly on the copier and slide it
to the front side.
(3) While closing it slowly, adjust the RADF unit
to the position where the positioning pins fit
smoothly into the holes at the unit.
(4) Loosen 2 screws fixing a hinge at the exit side
and move the plate to the position where its
center hole and one at the copier side are met
together.
(5) Fix hinges at the feed and exit sides with 2
shouldered screws (shown by white arrows).
(6) Tighten 2 screws loosened at the step (4).
Positioning pin
[Exit side]
[Feed side]
Plate