e-STUDIO550/650/810 TROUBLESHOOTING
5 - 110
JUNE 2002 © TOSHIBA TEC
Moire
Lack of sharpness
A
B
(3) Moire/lack of sharpness
Defective area
Step
Check Items
Prescription
Remarks
Density reproduction
1
Check the reproduction of the Adjust the density.
image density.
Parameter adjustment
2
Check the image processing
Check the adjustment value for
value
parameters.
sharpness.
Printer section
3
Check the printed image.
Make a test print using 04-113.
Perform the
appropriate trouble-
shooting if there is
any problem with the
image.
Defective area
Step
Check Items
Prescription
Remarks
Density reproduction
1
Check the reproduction of the Adjust the density.
image density.
Parameter adjustment
2
Check the image processing
Check the adjustment value for
value
parameters.
sharpness.
If it needs to be adjusted, check the
encircled areas A and B in the image,
and change the sharpness intensity
in the sharpness adjustment mode.
Printer section
3
Check the printed image.
Make a test print using 04-113.
Perform the
appropriate trouble-
shooting if there is
any problem with the
image.
Feeding direction