JUNE 2002 © TOSHIBA TEC
3 - 1
e-STUDIO550/650/810 ADJUSTMENT
3. ADJUSTMENT
3. 1. Hard Disk Formatting
<Procedure>
(1) Turn ON the power while the digital keys [0] and [8] are pressed simultaneously.
(2) Confirm that “Test Mode” is displayed on the control panel. Enter the code “690” and press the
[START] key. The display changes to “System Mode”.
(3) Enter the set value and press the [SET] or [INTERRUPT] key.
<Set value>
02: Initializing at the normal type
10: Initializing except information of the scanner template for the controller GA-1140
11: Initializing only information of the scanner template for the controller GA-1140
(4) “Wait” is displayed.
(5) Turn OFF the power after the message “REBOOT THE MACHINE” is displayed.
Note: The set value “10” and “11” are valid when the controller GA-1140 is installed and the HDD is
initialized at “2” (normal type). They are applied to the template used in the scanner function (needing
GE-1060).