e-STUDIO550/650/810 TROUBLE SHOOTING
5 - 74
JUNE 2002 © TOSHIBA TEC
[C85] Lifting tray motor error
Is the lifting tray lifted when originals are set on the feeding tray?
Is the loading of the lifting tray normal?
Adjust the mechanical loading. Remove, if any, extraneous
materials.
Is the power voltage for CN5-5 and CN6 on the ADF board 24V?
1. Replace the ADF board.
2. Perform the EEPROM initialization of RADF, sensor
automatical adjustment and tray width sensor adjustment.
Replace the lifting tray motor.
Is the upper limit sensor working properly when the lifting tray is lifted?
Replace the upper limit sensor.
Is the lifting tray lowered when originals are removed from the original tray?
Is the loading of the lifting tray normal?
Adjust the mechanical loading. Remove, if any, extraneous
materials.
1. Replace the lower limit sensor.
2. Replace the ADF board.
3. Perform the EEPROM initialization of RADF, sensor automatical adjustment and tray width
sensor adjustment.
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
NO
YES
Содержание e-studio550
Страница 115: ...JUNE 2002 TOSHIBA TEC 4 11 e STUDIO550 650 810 PREVENTIVE MAINTENANCE Rear side 20 74 75 32 80 63 44 73 75 53 ...
Страница 309: ...JUNE 2002 TOSHIBA TEC 8 1 e STUDIO550 650 810 WIREHARNESSCONNECTIONDIAGRAMS 8 WIRE HARNESS CONNECTION DIAGRAMS ...
Страница 313: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8442 JAPAN R02032112000 TTEC ...