(6) Check if the value
is within the range of 245 to 255 (the output voltage range of the auto-toner
sensor is 2.45 V to 2.55 V).
(7) If the value
is not within the range of 235 to 245%, press the Up or Down icon to adjust the
value manually.
Note:
The relation between the icons and the values
and
is as follows.
Icon to be pressed
Value
Value
Up
Increased
Increased
Down
Decreased
Decreased
(8) Press the [SET] icon or [INTERRUPT] key.
The drum, developer unit, etc. are stopped and the following is displayed.
(9) Enter “290” using the digital keys and press the [START] key. (enforced performing of image quality
control)
The display changes as follows.
(10)After the operation has finished, the copier are automatically stopped and the following is displayed.
(11)Turn OFF the power.