JUNE 2002 © TOSHIBA TEC
5 - 107
e-STUDIO550/650/810 TROUBLESHOOTING
Feeding direction
Image density
Gray balance
5.2 Troubleshooting for Image
(1) Abnormality of image density/Gray balance
Defective area
Step
Check Items
Prescription
Remarks
Density/Gray balance
1
Check the density/gray balance.
Adjust the density.
Printer section
2
Check the printed image.
Make a test print using 04-113 and
Go to step 4
check it.
If there is any
problem on
the image.
Scanner
3
Are the original glass or mirrors
Clean them.
dirty?
Printed image
4
Is the image faded?
Perform troubleshooting for faded
image.
Is background fogging occuring?
Perform troubleshooting for
background fogging.
Is there a blotch on the image?
Perform troubleshooting for blotched
image.
Is the image transferred normally?
Perform troubleshooting for
abnormal transfer.