36
displays the function menu for this parameter, this parameter can be changed via the soft-key ON or
OFF
OC Fold
1)
Description
This parameter is used to set whether to enable the over-current fold function. When this parameter
is set to "ON", the output voltage will decrease due to the load increased, the current output will be
kept constant at current high limit. (Note: After this function is enabled, the current will output only if
the output current is greater than the current high limit setting value.) When this parameter is set to
"OFF", the over-current fold function is turned off.
2)
Operation
Make use of the
key or the knob to move the cursor to this parameter option, the soft-key zone
displays the function menu of this parameter, this parameter can be changed via the soft-key ON or
OFF.
LoopCycle
1)
Description
This parameter indicates the total number of cycles for all memory sequences when the step
connection is turned on. Set to "000", indicating continuous loop output of current memory sequence;
Set to "001~999", indicating the memory sequence will be cycled several times based on your setting.
See program setting function for details.
2)
Operation
Make use of the
key or the knob to move the cursor to this parameter option, then change it with
the front panel numeric keys, and finish with ENTER or OK keys to confirm the change. If you do not
want to change the parameter value or press the wrong numeric key when changing with the numeric
keys, you can cancel it by pressing the
key or ESC key.
SingleStep
1)
Description
This parameter is used to set whether to manually enter the next step. When this parameter is set to
“ON”, after the first step of test is finished you need to press the ON/OFF button to execute the next
step; When this parameter is set to "OFF", the next step will be automatically executed at the end of
the 1st step of test.
2)
Operation
Make use of the
key or the knob to move the cursor to this parameter option, the soft-key area
displays the function menu of this parameter. This parameter can be changed by soft keys.