35
This parameter is used to set the starting angle phase of the output waveform, which ranges from 0 to
359
°
.
2)
Operation
Make use of the
key or the knob to move the cursor to this parameter option, then change it with
the front panel numeric keys, and finish with ENTER or OK keys to confirm the change. If you do not
want to change the parameter value or press the wrong numeric key when changing with the numeric
keys, you can cancel it by pressing the
key or ESC key.
OFFPHS
1)
Description
This parameter is used to set the ending angle phase of the output waveform, which ranges from 0 to
359
°
.
2)
Operation
Make use of the
key or the knob to move the cursor to this parameter option, then change it with
the front panel numeric keys, and finish with ENTER or OK keys to confirm the change. If you do not
want to change the parameter value or press the wrong numeric key when changing with the numeric
keys, you can cancel it by pressing the
key or ESC key.
Results
1)
Description
This parameter is used to set the status of the display page of the last test result, there are three
modes: “LAST”, “ALL” and “P/F”. When set to "LAST", the display will show the final test result after the
test is over; When set to “ALL”, the display will show all test results after the test is over; When set to
“P/F”, the display will show “PASS” or “FAIL” after the test is over. In the manual mode, when the
voltage output value and the frequency value are in the range of the high voltage limit, the low
voltage limit, the high frequency limit, and the low frequency limit, “PASS” is displayed at the end of
the test; If it is not within the range, “FAIL” is displayed, out of range is displayed, and shows the
parameter values that are out of range. For details, please refer to result display function.
2)
Operation
Make use of the
key or the knob to move the cursor to this parameter option, the soft-key zone
displays the function menu of this parameter, this parameter can be changed by the soft-key LAST,
ALL or P/F.
Surge/Drop
1)
Description
This parameter is used to set whether to enable the Surge/Drop function. When this parameter is set
to “ON”, the MEMORY page will display “SD Volt”, “SD Site”, “SD Time”, “SD Cont”; When this
parameter is set to "OFF", these parameters are not displayed. For details, please refer to Surge/Drop
function.
2)
Operation
Make use of the
key or the knob to move the cursor to this parameter option, the soft-key zone
Содержание TH7105