137
2)
Send Instruction Format
3)
Return Instruction Format
The return command data byte range is 0--20.
6.4.3.12
Address 12 (SD Time)
1)
Command Description
This command is used to query the time width of the surge drop in manual mode.
2)
Send Instruction Format
3)
Return Instruction Format
The return command data byte range is 0--20.
6.4.3.13
Address 13 (SD Connection)
1)
Command Description
This command is used to query the SD connection status of the surge drop in manual mode.
2)
Send Instruction Format
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x03
0x00
0x0B
0x00
0x01
Calculated based on the first 6
bytes
Instrument
address
Function
Code
Number of
Data
Data Byte1
Data Byte2
CRC Low
CRC High
1~32
0x03
0x00
0x00
0~20
Calculated based on the first 5
bytes
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x03
0x00
0x0C
0x00
0x01
Calculated based on the first 6
bytes
Instrument
address
Function
Code
Number of
Data
Data Byte1
Data Byte2
CRC Low
CRC High
1~32
0x03
0x00
0x00
0~20
Calculated based on the first 5
bytes
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High