125
1~32
0x10
0x00
0x33
0x00
0x01
0x01
0x00
0x00
or
0x01
Calculated based
on the first 8 bytes
3)
Return Instruction Format
6.4.2.51
Address 52 (Voltage High Limit)
1)
Command Description
This command is used to set the high voltage limit value in the programmed mode. The command data
range is 0.0~300.0V. Command is invalid when output is turned on
.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data byte 1~4
CRC
Low
CRC
High
1~32
0x10
0x00
0x34
0x00
0x02
0x04
0.0~300.0V, 4
bytes stored in
float point type
Calculated based on
the first 11 bytes
3)
Return Instruction Format
6.4.2.52
Address 53 (Voltage Low Limit)
1)
Command Description
This command is used to set the low voltage limit value in the programmed mode. The command data
range is 0.0~300.0V. Command is invalid when output is turned on
.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data byte 1~4
CRC
Low
CRC
High
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x33
0x00
0x01
Calculated based on the first 6
bytes
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x34
0x00
0x02
Calculated based on the first 6
bytes