II-12
Integration (Totalizing)
Totalized value is composed of an alphanumeric sequence and unit of measurement. The
alphanumeric display is expressed with a maximum of 7 digits. If the unit of flow is set as volumetric
flow, the selectable totalizing unit to be set will be in volumetric flow units.
If the unit of flow is set in mass flow units, the selectable totalized flow unit to be set will be in mass
flow units. However when setting mass flow units, it is necessary to know the density of the liquid
being measured.
Totalized values are retained even when power is turned off.
[Totalized display]
The alphanumeric sequence can be expressed up to 7 digits. Plus and minus independent
display range is 0 to 9999999.
There are no decimal points in the totalized value display. For example, if the totalized value is
100m
3
and totalized unit is set at x 1m
3
, ‘0000100x1m
3
’ is displayed. But if the totalized unit is set
at ×1000m
3
, the display will be ‘0000000x1000m
3
’ .
[Totalized units]
Totalized units can be selected from the following.
• When flow is set in volumetric flow units,
NONE, x10000m
3
, x1000m
3
, x100m
3
, x10m3, x5m
3
, x1m
3
, x100L, x10L, x1L, x100mL, x10mL
• When flow is set in volumetric of USA flow units,
ft
3
, kft
3
, Mft
3
, bbl, kbbl, Mbbl, gal, kgal, Mgal, acf, kacf, Macf
• When flow is set in mass flow units,
NONE, x100kt, x10kt, x1kt, x100t, x10t, x1t, x100kg, x10kg, x1kg, x100g, x10g, x1g
[Totalizing start and stop modes]
Totalizing can be selected for a fixed time either manually or with timer setting.
The [START] command initiates totalizing with a continuation of totalized values.
Totalizing can also be initiated from a preset value with the [PRESET START] command from the
preset menu.
The [STOP] command ends totalizing.
Timer setting enables totalizing operation for a predetermined time only.
The timer can be set up to 99h59m59s (i.e. 99 hours, 59 minutes, 59 seconds). When the set
time elapses, totalizing automatically ends.
During totalizing, an
‘I’
blinks at the upper right of the measurement screen and disappears when
totalizing ends.
Содержание UFL-30
Страница 1: ...Doc No KF08 001J Ultrasonic Flowmeter UFL 30 Installation Operation Manual ...
Страница 11: ... 10 blank ...
Страница 12: ...I Installation ...
Страница 60: ...II Operation ...
Страница 109: ...II 50 blank ...
Страница 110: ...III Other ...
Страница 123: ...III 14 III 2 5 Dimensions Main Unit ...
Страница 128: ...III 19 blank ...
Страница 129: ...III 20 blank ...
Страница 145: ...III 36 blank ...
Страница 165: ...III 56 blank ...