I- 40
sheath as shown. (Suggestion only)
You can skip this step.
(10) Wrap electrical tape or contained
self-adhesion tape
around the core lines.
(11) Join and solder the braids of the inner shield
together.
Joint must be double twisted as above.
(12) Wrap electrical tape around the inner shield.
Note; If return shield length is too short, please
use included metal net as extra-shield.
(13) Join and solder the braids of the ends of
the outer shield together and wrap with
electrical tape similar to steps (11) and
(12).
(14) Place the joined cable in the center of the
mold casing cavity.
(15) Seal the ends of the mold casing with tape.
(16) Attach funnels as shown in the photo
below.
(17) Mix and prepare the resin liquid then pour
it into the mold casing.
Allow resin to harden.
This completes the cable joint.