i. Flowmeter
self-diagnostics
Display Menu No.
: CHK-8 : [UF STATUS]
The flowmeter is equipped with a periodic self-check function.
Error Code
ERR01-TX
Transmitting Circuit, OK or NG (w/ No. of path)
ERR02-RX
Receiving Circuit, OK or NG (w/ No. of path)
ERR-04-COUNTER
Time Measuring Circuit, OK or NG
The result of time measuring
ERR08-ITG.MEMORY
RAM Check, OK or NG
ERR16-DATA MEMORY
ROM Check, OK or NG
ERR-32-PARAMETER
Consistency Check of Input Data, OK or NG
Note :
Regarding the detail of error codes, please refer to Table 4-1, ‘Error Code List’ under Chapter II-2-7.