6-56
(3-4) Using the rejector to set the minimum value of the noise table.
The minimum value of the noise table can be set by using the rejector. To operate the
rejector, set the rejector display in graph option on the echo viewer operation area to ON
( ). Use the mouse to directly click the displayed rejector, and then simply drag it
upward or downward to change the value. When the rejector is applied to the noise table, the
noise table will be considered edited and will be displayed in the update color.
Fig. 6.8.8 Setting the minimum value of the noise table using the rejector
To write the noise table to the device, click [Noise Table] --> "Write" button. The updated
points are written to the device. If the noise table point values are smaller than the rejector
values, rejector values are written.
Current rejector value
Left click and drag