6-58
(More
than
0.0m)
- Exclusion Range
Range of the auto noise table exclusion area
(More
than
0.0m)
After setting value confirmation, if you click "Next", the following window will be displayed.
Fig. 6.8.11 Noise table automatic creation dialog box
If you click "OK", the noise table will be automatically set in the echo curve data that is
displayed. The noise table included in the auto noise table exclusion area is linearized. When
the noise table covers the surface echo, adjust again so that the noise table does not cover
the surface echo.
To write the noise table to the device, click [Noise Table] --> "Write" button. All points are
written to the device.