10-1
Chapter 10 Technical data
10.1 General specifications
Table 10.1.1 General specifications
Measurement
principle
The time-of-flight measurement principle with microwave pulses
Medium Liquid/Solid
Liquid
Dielectric constant
ε
r
≥
1.8
Process Temperature
Non-Ex
Cone antenna
FKM:-10 to +150 °C
Kalrez:-20 to +150 °C
VMQ:-40 to +150 °C
PTFE sealing antenna
FKM:-10 to +200 °C
VMQ:-40 to +180 °C
Rod antenna
VMQ:-40 to +150 °C
NOTE:
・
For Ex equipment, please refer to the “Safety
Instructions”.
・
Temperature range differs depending on the O-ring
material.
・
FKM(Fluorine-containing rubber)
・
Kalrez(Kalrez6375)
・
VMQ(Silicone rubber)
・
The maximum temperature of Ex-types is due to
temperature class and ambient temperature of Ex.
Process pressure
Cone antenna
-0.1 to +1.5 MPa
PTFE sealing antenna
-0.1 to +1.5 MPa
Rod antenna
-0.1 to +1.5 MPa
Maximum
measuring
range
4" cone antenna
30m
2" cone antenna
10m
4" PTFE sealing antenna 30m
2" PTFE sealing antenna 10m
1" rod antenna
5m
NOTE:
It is a consequence in our environment. It may vary depending on the
installation environment and the measurement object.
Содержание KRG-10
Страница 1: ...Document No KF13 001K Microwave Level Gauge RG 10 User s Guide...
Страница 9: ...8 Blank...
Страница 13: ...12 Blank...
Страница 17: ...1 4 Fig 1 2 4 Transmitter head with rod antenna 1 Transmitter head 2 Flange option 3 1 rod antenna...
Страница 51: ...3 8 Blank...
Страница 55: ...4 4 Blank...
Страница 171: ...9 2 Blank...
Страница 181: ...10 10 10 4 Optional specifications Table 10 4 1 Optional specifications CD R Configuration software...
Страница 190: ...10 19 M20 1 5 Fig 10 7 6 Cable gland Only Non Ex type...
Страница 193: ...11 2 Blank...
Страница 197: ...12 4 Blank...
Страница 199: ...Blank...