5-18
[6-3] Slow Search Speed
Set the distance per second to enlarge the effective window during slow search.
The distance to be enlarged varies depending on the search time.
Note:
・
Search time[s] =
“
Boot Mode
”
setting,
“
Normal
”
15 sec /
“
Fast
”
4 sec
・
Slow Search Speed[d] = speed [m/sec]
×
Search time [sec]
Distance
S
ignal
Amplitu
de
Valid Window
t1
t2
d
:
Slow Search Speed
Wd(t2)=Wd(t1)+2d
Wd(t1)
d
d
Fig. 5.4.11 Slow search
[6-4] Empty Tank Detection
While this function is "On", liquid level “0” will be outputted if the last position of surface echo was lower
than empty tank detection position when echo was lost.
0: Off
1: On
[6-5] Empty Tank Detection Position
Enter a threshold value (distance from tank bottom) as empty tank detection position to recognize
measured level as empty level (Parameter [R]+[C]) if measured level is lower than the threshold value.
Signal
Ampli
tude
Fig. 5.4.12 Empty Tank Detection
[7-0] Fixed Current Output
Enter a current value to fix output current from the transmitter for output calibration.
When the fixed current output is set to 0mA, fixed current mode is canceled and current value that
selected as
[3-0] Analog Current Output Parameter
is output. In addition, fixed current mode is
canceled by turning on a power supply again or performing
[8-2] Reboot
.
Содержание KRG-10
Страница 1: ...Document No KF13 001K Microwave Level Gauge RG 10 User s Guide...
Страница 9: ...8 Blank...
Страница 13: ...12 Blank...
Страница 17: ...1 4 Fig 1 2 4 Transmitter head with rod antenna 1 Transmitter head 2 Flange option 3 1 rod antenna...
Страница 51: ...3 8 Blank...
Страница 55: ...4 4 Blank...
Страница 171: ...9 2 Blank...
Страница 181: ...10 10 10 4 Optional specifications Table 10 4 1 Optional specifications CD R Configuration software...
Страница 190: ...10 19 M20 1 5 Fig 10 7 6 Cable gland Only Non Ex type...
Страница 193: ...11 2 Blank...
Страница 197: ...12 4 Blank...
Страница 199: ...Blank...